indigo system lightning 12

INDIGO Aspiration Tubing: As part of the INDIGO Aspiration System, the INDIGO Sterile Aspiration Tubing is indicated to connect the INDIGO CAT RX Aspiration Catheters to the Penumbra Aspiration Pump. New York, New York Penumbra, Inc. The device is intended for single use only. The PRISM trial, a retrospective case analysis assessing the rate of TIMI 2-3 flow after the use of Indigo and specifically the XTRACT technique, showed an 87.2% rate of revascularization post-Indigo and subsequent treatment of underlying stenosis in the same setting.1 The newly completed study studying the same primary outcome as PRISM, the INDIAN registry, showed an even higher rate of revascularization, 88.7%.2 Sustained aspiration for ALI could potentially increase the revascularization rate by serving as an effective single-session frontline option. The Indigo System aspiration catheter is available in a range of lengths and diameters that, when connected to the proprietary Penumbra Aspiration Pump, may help atraumatically remove the thrombus under continuous aspiration. Intravascular ultrasound (IVUS) revealed May-Thurner syndrome, which was treated with stenting in the CIV and EIV; 100% of the clot was resolved (, The newly available Indigo CAT12 Aspiration Catheter (Penumbra, Inc.) was utilized to perform mechanical thrombectomy of the FV, CFV, and EIV and CIV without the use of thrombolytics (, Significant thrombus was aspirated from the Indigo CAT12 Aspiration Catheter (, May-Thurner narrowing of the left CIV was noted and treated with a Vici stent (Boston Scientific Corporation), with IVUS before treatment (, IVUS after thrombectomy and stenting showed a widely patent lumen (. The on-table PA pressures were statistically reduced, and the median device time was 37 minutes. CAT3 advanced through the pedal loop (C). Lightning 12 combines the Indigo System CAT12 Aspiration Catheter with Lightning Intelligent Aspiration, enabling physicians to focus on optimizing thrombus removal using the systems unique clot detection mechanism. Penumbra sells its products to hospitals and healthcare providers primarily through its direct sales organization in the U.S., most of Europe, Canada and Australia, and through distributors in select international markets. Use of LIGHTNING Aspiration Tubing adjacent to other equipment should be avoided because it could result in improper operation. Common emitters (such as RFID emitters, security systems, diathermy equipment, and portable transmitters) should not be used in close proximity to the PENUMBRA ENGINE as they can interfere with and result in degradation of the performance of the equipment. When the catheter is engaged on thrombus or embolic material, the clicking sound ceases. Use the INDIGO Aspiration System in conjunction with fluoroscopic visualization. Do not use kinked or damaged devices. Co-Director, Aortic Institute The patient had a history of lower left extremity venous thrombus dating back to 2013, with chronic residual nonocclusive popliteal vein thrombus in 2018. Eric Moldestad, MD Potential adverse . 2023 Bryn Mawr Communications II, LLC. The Indigo Aspiration System with Lightning 12 removes these difficult-to-access, life-threatening clots, potentially reducing the need for thrombolytics and their associated ICU stays. The wire was removed, and the CAT8 was used to remove thrombus from the popliteal artery. Do not use in the presence of a flammable anesthetic mixture with air or nitrous oxide. Excessive aspiration or failure to close the INDIGO Aspiration Tubing valve when aspiration is complete is not recommended. Venogram showing stents in the left CIV and EIV. Use prior to the Use By date. CAT12 is a large . Placing guidewire too distal in the pulmonary vasculature or excessive manipulation of aspiration/ guiding catheter in the smaller, peripheral, and segmental pulmonary artery branches can result in vessel perforation. CAT12 is . Stay informed on the week's top stories including literature summaries, device approvals, guideline changes, and more. It will reduce the service life of the PENUMBRA ENGINE. Do not resterilize or reuse. Circulation. Saxon RR, Benenati JF, Teigen C, et al. Using the HTORQ angle on CAT12 to torque the catheter, several passes were made through the affected area, from the left popliteal to the external iliac vein (EIV) and internal iliac vein. Utility of a power aspiration-based extraction technique as an initial and secondary approach in the treatment of peripheral arterial thromboembolism: results of the multicenter PRISM trial. INDIGO Aspiration System Indication for Use Do not resterilize or reuse. Contraindications There are no known contraindications. Penumbra Aspiration Pump: The Penumbra Aspiration Pump is indicated as a vacuum source for Penumbra Aspiration Systems. Disclosures: None. The Indigo Systems proprietary Separator technology, Separator 12 is also available with Lightning 12 and is designed to enable unobstructed aspiration for the duration of the procedure. The SEP12 was introduced to help clear the lumen of the catheter due to the heavy thrombus burden. Lightning was hooked up to the Indigo System Catheter CAT12 and placed into the access sheath. A 57-year-old man presented with acute-onset left calf pain for the past 10 days and had recently taken a 4-hour flight. Return all damaged devices and packaging to the manufacturer/distributor. Any forward-looking statements are based on our current expectations, estimates and assumptions regarding future events and are applicable only as of the dates of such statements. Thrombolysis is not a universal option for all patient groups, especially if the patient has an absolute or relative contraindication to a fibrinolytic agent. Lightning 12 combines the new Indigo System CAT12 Aspiration Catheter with Lightning Intelligent Aspiration, enabling physicians to focus on optimizing thrombus removal using the system's unique clot detection mechanism . With the maximized inner diameter of 0.082 and a 7 French outer diameter, CAT7 is 93% the size of CAT8, now with a lower profile. Internet Explorer presents a security risk. Lightning is paired with CAT8 or CAT12. When performing aspiration, ensure that the INDIGO Aspiration Tubing is open for only the minimum time needed to remove thrombus. Industry Prospects Do not use open or damaged packages. Figure 1. At discharge, there have been no adverse device events, and clinical success at 1 month (defined as the absence of death and limb loss) is 98.6%.4. The Indigo System has demonstrated high rates of revascularization with consistent success. Do not use kinked or damaged devices. These risks and uncertainties, as well as others, are discussed in greater detail in our filings with the Securities and Exchange Commission, including our Annual Report on Form 10-K for the year ended December 31, 2019 filed with the SEC on February 26, 2020, our Quarterly Report on Form 10-Q for the quarter ended March 31, 2020 filed with the SEC on May 7, 2020, our Quarterly Report on Form 10-Q for the quarter ended June 30, 2020 filed with the SEC on August 3, 2020, and our Quarterly Report on Form 10-Q for the quarter ended September 30, 2020 filed with the SEC on November 2, 2020. In addition, the RV/LV ratio decreased from 2.26 to 1.09, over a > 50% on-table decrease. Lightning 12 and Separator 12 are designed for the removal of fresh, soft emboli and thrombi from the peripheral arterial and venous systems, and for the treatment of pulmonary embolism. The new Indigo System is engineered to allow for thrombectomy while helping to prevent excessive blood loss during the procedure. In the current treatment of PE, standard treatments such as anticoagulation, thrombolysis, and open embolectomy have limitations. Prior to use, please refer to Instructions for Use for complete product indications, contraindications, warnings, precautions, potential adverse events and detailed instructions for use. Program Director, Vascular Fellowship & Integrated Residency This website is intended for US audience only. The Indigo Aspiration System provides a treatment option that is now cleared by the FDA to treat PE. The Indigo System Lightning 12 is the companys newest generation aspiration system for peripheral thrombectomy. The Indigo System Lightning 12 was launched in July and is available immediately for patients needing interventional treatment for PE. Available in a selection of sizes, the CAT family can provide access to distal peripheral vessels of the upper and lower extremities, including below the knee. Only use replacement fuse with correct rating (see Table 1 for fuse rating). The Indigo System with . The Indigo System with Lightning Aspiration Tubing is an intelligent aspiration system powered by Penumbra ENGINE. Dr. Arko is chief, Division of Vascular and Endovascular Surgery, Sanger Heart and Vascular Institute in Charlotte, North Carolina. Blood clots in the lungs can block the lungs from absorbing oxygen, causing strain on the heart and other organs. Penumbra, Inc. J Vasc Surg. Indigo, now with Lightning, utilizes a unique mechanism of action to help optimize thrombus removal procedures by differentiating between thrombus and blood. The patients right leg was completely cold, insensate, and immobile from the thigh down. Maintain a constant infusion of appropriate flush solution. The sustained aspiration from the Penumbra ENGINE provides constant uninterrupted full-vacuum aspiration throughout the procedure, addressing the constraints of syringe-based large-bore embolectomy, which include vacuum dropoff from the syringe filling with fluid. Do not use the INDIGO Aspiration System with a pump other than the Penumbra Aspiration Pump. As part of the Indigo Aspiration System, the Indigo CAT RX Aspiration Catheters and Indigo Separator 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature. INDIGO Aspiration Catheters and Separators: As part of the INDIGO Aspiration System, the INDIGO Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems, and for the treatment of pulmonary embolism. In summary, Lightning 12 is an excellent addition to the peripheral thrombectomy armamentarium and may allow for successful treatment of complex patients. Warnings Do not use the INDIGO Aspiration System with a pump other than a Penumbra Aspiration Pump. Lightning 12 combines the Indigo System CAT12 Aspiration Catheter with Lightning Intelligent Aspiration, enabling physicians to focus on optimizing thrombus removal using the system's unique clot detection mechanism. Figure 2. Poor distal runoff from acute thrombus. Mean PA pressure at the start of the case was 35 mm Hg. For more information on the personal data that is collected by this website, please refer to Penumbras Privacy Notice. Indigo, now with Lightning, utilizes a unique mechanism of action to help optimize thrombus removal procedures by differentiating between thrombus and blood. Lightning 7 a and Lightning 12 a are made of laser-cut hypotube technology, designed to increase trackability and torqueability. For more information on the personal data that is collected by this website, please refer to Penumbras Privacy Notice. There was poor distal runoff after wire crossing, indicating acute thrombus (, The Indigo System Catheter CAT8 was used in the superficial femoral artery (SFA) with several passes until flow was restored and the patient could move and feel his leg again (. Learn more about Lightning. o The Indigo catheters vary in diameters from 3.4Fr to 12Fr. The goal of this study is to create a prospective multicenter study that provides safety and performance data on the Indigo System as a frontline percutaneous aspiration thrombectomy approach for ALI patients for whom immediate treatment and revascularization can maintain limb viability. Venogram showing CAT12 in the CIV. The results may not be predictive of all patients. Pulmonary embolism, or PE, is a deadly condition causing blood clots within a patients lungs that has grown in prevalence during the COVID-19 pandemic.

Fremont Police Chase Today, Swot Analysis Of A Tuck Shop, Articles I